PART TWO: some main issues during the sewage treatment process and their corresponding solutions!1, The liquid level foam is slightly greenReaso...
Published on by Lan Yang, sewage/wastewater treatment, equipment manufacturer, contractor, operator
1, The liquid level foam is slightly green
Reason for occurrence: Insufficient anaerobic treatment may occur in municipal wastewater.
Solution: Strengthen the anaerobic treatment process to ensure that the wastewater stays in the anaerobic tank for a sufficient amount of time.
2, COD、 Ammonia nitrogen, TP and other indicators do not meet the standards
Reason: The treatment process failed to effectively remove these pollutants.
Solution: Adopt more efficient biological treatment processes, such as A/A/O processes (anaerobic/anoxic/aerobic), or introduce advanced treatment technologies such as membrane filtration.
3, Sludge expansion and floating sludge
Reason: Excessive sludge load, insufficient or excessive aeration, improper sludge age, etc.
Solution: Reasonably control the sludge load and aeration rate, extend the sludge age, and avoid sludge expansion by adjusting the inlet load.
What else problems do you come across during sewage treatment process? Let’s talk about.