Your Activated Sludge Design project for Malaysia (5171) is finished.

Influent parameters provided by the project designer:

Parameters Annual average Units
COD 500 mg/l
BOD5 250 mg/l
Total Suspended Solids (TSS) 300 mg/l
Total Kjeldahl Nitrogen (TKN) 50 mg/l
Total Phosphorous (TP) 10 mg/l
Design minimum wastewater temperature (Tmin) 26 °C
Design maximum wastewater temperature (Tmax) 29 °C