Groote Weilen CAS design for Benchmarking in Netherlands (3691)

Published on by in Completed Designs

Your Activated Sludge Design project for Netherlands (3691) is finished.

Influent parameters provided by the project designer:

Parameters Annual average Units
COD 0 mg/l
BOD5 280 mg/l
Total Suspended Solids (TSS) 215 mg/l
Total Kjeldahl Nitrogen (TKN) 65 mg/l
Total Phosphorous (TP) 12 mg/l
Design minimum wastewater temperature (Tmin) 14.5 °C
Design maximum wastewater temperature (Tmax) 23 °C

You can access your documents using the following links:

Design Basis
Process Scheme
Technical Description
Equipment List
OPEX
General Arrangement