New Device Simplifies Measurement of Fluoride Contamination in Water
Published on by Water Network Research, Official research team of The Water Network in Technology
Seeking to address fluoride contamination in drinking water, chemical engineers at EPFL have developed a portable and user-friendly device that can measure fluoride concentration accurately and reliably.
Image Source: Ecole Polytechnique Fédérale de Lausanne
Adding fluoride to water has been common practice in a number of countries, including the US, Australia, Brazil, Malaysia, India, and Vietnam. In low concentrations (below 1.5 mg/L) can help prevent tooth decay and even strengthen bones, but going above that can have the opposite effect, causing serious dental and bone disease, especially in children and developing fetuses.
To keep things in check, the WHO has set 1.5 mg/L as the maximum limit for fluoride in drinking water. “To determine whether drinking water is safe we need to detect fluoride in water at the level of parts-per-million (ppm),” says Kyriakos Stylianou at the Laboratory of molecular simulation at EPFL Valais Wallis. “Around 1-1.5 ppm is good for teeth, but in many countries, the water sources have concentrations above 2 ppm can cause serious health issues.”
But measuring fluoride at such low concentrations with sufficient accuracy is expensive and requires a well-equipped chemical lab. Because of this, fluoride contamination in water affects a number of developing countries today and even parts of developed countries.
Led by Stylianou, a team of scientists has now built a device that can accurately measure fluoride concentrations using only a few drops of water – even with low-level contamination – resulting in a simple change in color brightness. Published in the Journal of the American Chemical Society (JACS), the device is named SION-105, is portable, considerably cheaper than current methods, and can be used on-site by virtually anyone.
A diagram of the SION-105 prototype device: A vial containing a red luminescent suspension of SION-105 crystals is placed inside the device. When two drops of water sample are added to the vial, resulting changes in the brightness of SION-105 are measured by the photodiode, and instantly converted into an accurate quantitative reading of the fluoride concentration in the sample. The inset is a schematic of how the luminescence is quenched at the molecular level. Credit: Mish Ebrahim
The key to the device is the design of a novel material that the scientists synthesized (and after which the device is named). The material belongs to the family of “metal-organic frameworks” (MOFs), compounds made up of a metal ion (or a cluster of metal ions) connected to organic ligands, thus forming one-, two-, or three-dimensional structures. Because of their structural versatility, MOFs can be used in an ever-growing list of applications, e.g. separating petrochemicals, detoxing water, and getting hydrogen or even gold out of it.
SION-105 is luminescent by default but darkens when it encounters fluoride ions. “Add a few droplets of water and by monitoring the color change of the MOF one can say whether it is safe to drink the water or not,” explains Mish Ebrahim, the paper’s first author. “This can now be done on-site, without any chemical expertise.”
A photograph of SION-105 suspended in solvents with (L) and without (R) fluoride ion contamination. Credit: Mish Ebrahim
The researchers used the device to determine the fluoride content in different groundwater samples from Vietnam, the United Arab Emirates, and Saudi Arabia. The data corresponded very well when compared to measurements made using ion chromatography, a standard method for measuring fluoride concentration in water.
“This comparison showcases the performance and reliability of SION-105, which, coupled with the portability and ease-of-use of the device, make it a very user-friendly solution for water sampling in remote areas where frequent fluoride concentration monitoring is paramount,” says Stylianou.
Having confirmed the successful function of SION-105 and the device, EPFL has now filed a patent application for it. The device was developed by scientists at the Laboratory of molecular simulation, the Laboratory of Organometallic and Medicinal Chemistry, and the Electronic Workshop at EPFL Valais Wallis.
The research was funded by Swiss National Science Foundation (Ambizione Energy Grant and NCCR-MARVEL).
References
Fatmah Mish Ebrahim, Tu N. Nguyen, Serhii Shyshkanov, Andrzej GÅ‚adysiak, Patrick Favre, Anna Zacharia, Grigorios Itskos, Paul J. Dyson, Kyriakos C. Stylianou. "Selective, fast-response and regenerable metal–organic frame-work for sampling excess fluoride levels in drinking water". Journal of the American Chemical Society 11 February 2019. DOI: 10.1021/jacs.8b11907
Media
Taxonomy
- Public Health
- Pathogen Removal
- Pollutants
- Drinking Water Security
- Environmental Health
- Heath & Safety
- Water Pollution
- Treatment
- Decontamination
- Drinking Water Treatment
- Water Treatment & Control
- Decontamination
- Technology
- Research
- Contaminant Removal
- Disinfection
- Fluoride