Your Activated Sludge Design project for Brazil (5781) is finished.

Influent parameters provided by the project designer:

Parameters Annual average Units
COD 780 mg/l
BOD5 350 mg/l
Total Suspended Solids (TSS) 330 mg/l
Total Kjeldahl Nitrogen (TKN) 70 mg/l
Total Phosphorous (TP) 9 mg/l
Design minimum wastewater temperature (Tmin) 19 °C
Design maximum wastewater temperature (Tmax) 23 °C

You can access your documents using the following links:

Design Basis 
Process Scheme 
Technical Description 
Process & ​Instrumentation ​diagram 
Equipment List 
Instrumentation list 
OPEX 
General Arrangement 
Civil Bill of Quantites