Groote Weilen CAS design for Benchmarking in Netherlands (3691)

Your Activated Sludge Design project for Netherlands (3691) is finished.

Influent parameters provided by the project designer:

Parameters Annual average Units
COD 0 mg/l
BOD5 280 mg/l
Total Suspended Solids (TSS) 215 mg/l
Total Kjeldahl Nitrogen (TKN) 65 mg/l
Total Phosphorous (TP) 12 mg/l
Design minimum wastewater temperature (Tmin) 14.5 °C
Design maximum wastewater temperature (Tmax) 23 °C

You can access your documents using the following links:

Design Basis
Process Scheme
Technical Description
Equipment List
OPEX
General Arrangement