Test_OCS_Egypt in Egypt (5117)

Published on by in Completed Designs

Your Activated Sludge Design project for Egypt (5117) is finished.

Influent parameters provided by the project designer:

Parameters Annual average Units
COD 706 mg/l
BOD5 436 mg/l
Total Suspended Solids (TSS) 429 mg/l
Total Kjeldahl Nitrogen (TKN) 29 mg/l
Total Phosphorous (TP) 8 mg/l
Design minimum wastewater temperature (Tmin) 20 °C
Design maximum wastewater temperature (Tmax) 30 °C

You can access your documents using the following links:

Design Basis
Process Scheme
Technical Description
Process & Instrumentation diagram
Equipment List
Instrumentation list
OPEX
General Arrangement
Civil Bill of Quantites
Comparison Document

Taxonomy