test case9 in Costa Rica (2388)

Published on by in Completed Designs

Your Activated Sludge Design project for Costa Rica (2388) is finished.

Influent parameters provided by the project designer:

Parameters Annual average Units
COD 350 mg/l
BOD5 150 mg/l
Total Suspended Solids (TSS) 250 mg/l
Total Kjeldahl Nitrogen (TKN) 45 mg/l
Total Phosphorous (TP) 6 mg/l
Design minimum wastewater temperature (Tmin) 20 °C
Design maximum wastewater temperature (Tmax) 24 °C

You can access your documents using the following links:

Design Basis
Process Scheme
Technical Description
Equipment List
OPEX
General Arrangement

Taxonomy