Ive seen you have posted ...
Published by Muthu Bharathi, Environment Manager at Aarti Industries Ltd
Ive seen you have posted multiple queries.
There is a little more clarity needed on the question.
If you want to calculate the dosages, these will be depended on the quality of makeup of water & COC.
If you want to know , a better way to dose, direct dosing in the pumping or basin are practiced generally.
3 Comments
Published by Ennio Rezende, Principal Founder and Chief Consultant at WaterScience ltda
Sugest you follow Muthu Bharathi´s comments. Take a simple and safe approach. Yours is a simple problem and there are several simple ways to solve it.
Published by Ennio Rezende, Principal Founder and Chief Consultant at WaterScience ltda
ok tnx. actually i want know if i was have 100 kg corrosion inhibitor and 100 kg scale dispersantŘ then can i mix them together to get a mix corrosion inhibitor and dispersant for injection by pump in basin? Is this ratio (50%, 50%) correct?
blow down: 70m3/hrs
caH: 800ppm
coc: 2
make up caH: 400ppm
evaporation:35m3/hrs
average ambient temp: 40 celsius
Published by Alireza Haghighat Nejad
1 Comment
No.
You have to contact the supplier of the Corrosion Inhibitor & Scale Dispersant with these data.
or get data on the composition of these.
Based on these data, you can decide the qty needed to mix.
Also, its better to dose them separately to prevent any interaction of these active substances.
Published by Muthu Bharathi, Environment Manager at Aarti Industries Ltd